Specifications

ULTRASONIC INTELLIGENT SENSOR

Principle of operation Ultrasonic intelligent sensor, Active ultrasound, guided waves
Sensor electronics
CEMAT II
Inputs
32 Ch.
Power consumption Normal operation: 6,5 W
Selftesting Yes
Sensor output Digital
Enclosure standard
IP66 / IP68 (7 days @ 3 bar) / Nema type 4, 4X
Enclosure material
AISI 316 Stainless Steel
Dimensions / Weight
406 mm x 406mm x163 mm / 15 kg
Ambient temperature
-40 °C to +60 °C (-40 °F to +140 °F)
Operating pipe temperature
-40 °C to +180 °C (-40 °F to +360 °F)
Method of installation Head Unit to be placed near pipe, transducers to be in contact with pipe
Signal output
Signal protocol
RS485
Modbus RTU
Two-way communication Yes
Software upgrading Yes
Sensor configuration Up to 32 transducers
Coverage distance max. 2 m (80”)

CORROSION & EROSION MONITOR TECHNICAL DATA

Minumum pipe diameter
100 mm (4”)
Pipe-wall thickness range
8 mm to 50 mm (0,3″ to 2″)
Distance between transceivers
0,15 m to 1 m (6″ to 40″)
Response time
Real-time
Sensitivity
0,1% of wall thickness. The presence of liquid in the pipe does not affect sensitivity
Fluid in pipe
Oil, gas, water, multiphase or other liquids
Pipe material
All metal pipes
Calibration
Once, on installation
Cabel interface
0,25 mm2 to 2,5 mm2 (AWG 24 to AWG 12)

COMPUTER

Minimum hardware
Computer: Pentium III (or equivalent) with 512 MB RAM
Controller: Fieldpoint or RIO Programmable Automation Controller (PAC)
Software requirements (for Clampon Software) Windows 2000-2008 /Vista / XP/10
Signal output Serial, Modbus, Ethernet
SAFE AREA EQUIPMENT
Mains power supply 18 VDC to 32 VDC or 100-260 VAC 50-60 Hz
Power consumption Maximum 6,5 W per sensor

Hazardous area approval

ATEX
IECEx
cULus
II 2 G Ex e mb IIC T6…T3 Gb, zone 1
Ex e mb IIC T6…T3 Gb, zone 1
Class I Division 2, Groups A,B,C,D, T6…T3