Specifications

ULTRASONIC INTELLIGENT SENSOR

Principle of operation Ultrasonic intelligent sensor, Active ultrasound, guided waves
Sensor electronics
DSP 66 MIPS, A/D converter 24bit, 5MS/sec, 0-1MHz
Sensor electronics input bandwidth
0.02 – 2 MHz
Sensor electronics output 20-1500KHz, ±70 Volt
Inputs
32 Ch.
Power consumption Normal operation: 2.5 W
Selftesting Yes
Sensor output Digital
Enclosure standard
IP67
Enclosure material
AISI 316 Stainless Steel
Dimensions / Weight
240 mm x 180 mm x 155 mm/6 kg (13,2 lbs)
Max. pipe surface temperature
-40 to 180 °C (-40 to 356 °F)
Operating pipe temperature
-40 to 150 °C (-40 to 302 °F)
Method of installation Head Unit to be placed near pipe, transducers to be in contact with pipe
Interface options
RS485
Two-way communication Yes
Software upgrading Yes
Sensor configuration Up to 32 transducers
Distance to main sensor 0.15-1m (6”- 40”)
Coverage distance max. 2 m (80”)

CORROSION & EROSION MONITOR TECHNICAL DATA

Pipe diameter
Min OD 75mm (3”)
Pipe-wall thickness
8-35 mm (0,315 – 1,378)
Pipe OD/wall thickness
>8
Distance between transceivers
0.15m to 2m
Response time
Real-time
Sensitivity
0,1% of wall thickness. The presence of liquid in the pipe does not affect sensitivity
Frequency range
20 to 1500 kHz
Fluid in pipe
Oil, gas, water, multiphase or other liquids
Pipe material
All metal pipes
Calibration
Once, on installation
Cabel interface
Cable with connector/Flying lead/Gland for cable access
Cabeling
Minimum 4x 0.75 mm2 (pending system configuration)

COMPUTER

Minimum hardware
Computer: Pentium III (or equivalent) with 512 MB RAM
Controller: Fieldpoint or RIO Programmable Automation Controller (PAC)
Software requirements (for Clampon Software) Windows 2000/2003/XP/Vista
Input Serial, Modbus, Ethernet, OPC
Signal output Serial, Modbus, Ethernet, 4-20mA, Relay, Client Server
SAFE AREA EQUIPMENT
Mains power supply 12 – 48 VDC or 100-260 VAC 50-60 Hz
Power consumption Max 2,5 W per sensor + computer rack module

INSTRINSICALLY SAFE (IS) APPROVAL

ATEX
II 2 (2) G Ex mb (ib) IIC T4, zone 1
II 2 (2) G Ex ib mb (ib) IIB T4, zone 1